The working principle of the CY high-precision film thickness controller involves technologies such as photomultiplier tubes, optical systems, vibrating slits and DC signals
The working principle of the CY high-precision film thickness controller involves technologies such as photomultiplier tubes, optical systems, vibrating slits and DC signals. These components work together to enable the film thickness controller to achieve precise control of film thickness. Specifically, the photomultiplier tube is used to detect the growth of the film, the optical system ensures the accuracy and efficiency of the detection, the vibrating slit is used to control the flow of the evaporated material, and the DC signal provides the necessary control signal. The CY film thickness controller has a wide range of application value and important technical advantages in the field of film preparation and quality control.
CY film thickness controller is a device used to accurately control the thickness of vacuum evaporated metal or non-metallic films. It can accurately measure and control the thickness of coatings, coatings and films, thereby ensuring the accuracy and quality of surface treatment processes. It is mainly used in magnetron sputtering coating machines, high vacuum evaporation coating machines, electron beam evaporation systems, PLD pulsed laser sputtering deposition equipment, multifunctional thin film deposition systems, etc.
Features:
1.High precision:Thickness controllers can provide high-precision measurement results. For example, high-precision film thickness gauges use imported high-quality sensors with a thickness measurement resolution of up to 0.1 microns, ensuring the stability and accuracy of the test results.
2.Wide application:The film thickness gauge is suitable for measuring the thickness of a variety of materials and products, including metals, plastics, ceramics, glass, etc. This is because these materials are good conductors of sound and can achieve high-precision detection services. In addition, the film thickness gauge can also be equipped with a variety of dual crystals with different frequencies and different chip sizes to achieve efficient product thickness measurement.
3.Intelligent control:LCD display, simple operation, equipped with USB interface, can record, store, print data and connect to computer and printer.
4.Small size:small and beautiful appearance, simple and easy to operate, long service life.
Contact us:
If you are interested in our film thickness tester, please contact us for more information and quotation.。
Tel:86 159 3625 3205
Email:zerlinda@zztainuo.com
Contact:Zerlinda
Wechat:86 159 3625 3205
WhatsApp:86 159 3625 3205
Technical Specifications:
Product name | CY High Precision Film Thickness Controller |
Product Model | CY-FTM60-TC |
Sensor input port | 2 pcs |
Film thickness resolution | 0.0136Å |
Film thickness accuracy | ±0.5%. |
Measuring speed | 100ms-1s/time, adjustable measurement range: 500000Å |
Communication Ports | RS-485 or RS-232 |
Storage capacity | 100 pcs |
Display Mode | LCD ,Support Chinese or English display |
Probe Type | Single chip, dual chip and multi chip optional |
Chip initial frequency | 6MHz |
Dimensions | L100 * W800* H50(mm) |
Weight | 15kg |
Main components:
Supplied Accessories | Display, sensor probe, flange, quartz wafer, etc. |
Product Manual | 1 copy |
Application case "Application of film thickness controller in evaporation coating machine"
Experimental preparation1.
1.Equipment inspection and calibration:
Ensure that the evaporation coating machine and film thickness tester are in good working condition.
Calibrate the film thickness tester according to its model and instructions to ensure the accuracy of the measurement.
2.Material preparation:
Prepare the substrate to be coated.
Prepare coating materials according to experimental requirements.
3.Environmental preparation:
Ensure that the laboratory environment meets the experimental requirements, such as temperature, humidity, etc.
Clean the workbench and ensure the experimental environment is tidy.
Experimental procedures
Substrate cleaning:
Use appropriate cleaning agents and methods to clean the substrate to remove impurities and oil stains on the surface.
After cleaning, rinse with deionized water and dry the substrate in an oven.
Substrate loading:
Place the dry substrate on the sample stage of the evaporation coating machine and fix the position.
Parameter settings:
Set the parameters of the evaporation coating machine according to experimental requirements, such as power, air pressure, time, etc.
Control film thickness: adjust the power of the evaporation source and the evaporation time according to the required film thickness
Start coating:
Start the evaporation coating machine, turn on the vacuum pump, start vacuuming, and when the vacuum degree reaches the requirement, turn on the evaporation source to start evaporation coating.
Monitor parameter changes during the coating process and record data.
Film thickness measurement:
After coating, take out the substrate and use the film thickness controller to measure the film thickness.
When measuring, pay attention to the selection of test points to ensure that the data is representative.
Data recording and analysis:
Record the film thickness measurement results and compare them with the expected results.
Analyze the consistency and uniformity of film thickness based on the measured data.
Experimental results evaluation:
Evaluate whether the experimental results are in line with expectations.
Analyze the results and find possible improvement measures.
Subsequent processing
Cleaning the device:
End of evaporation: After the thin film evaporation is completed, turn off the evaporation source and vacuum pump, restore the device to normal pressure, and ensure the cleanliness of the equipment and environment.
Summary and Report:
Summarize the experimental process and results and write an experimental report.
Include the experimental purpose, methods, results, discussion and conclusion.
Through the above steps, the film thickness test experiment can be effectively carried out on the evaporation coating machine to ensure the reliability and repeatability of the experiment.
Copyright © Zhengzhou CY Scientific Instrument Co., Ltd. All Rights Reserved Update cookies preferences
| Sitemap | Technical Support: