The magnetron sputtering coater is an advanced physical vapor deposition (PVD) equipment widely used in semiconductor, optoelectronics, display technology, surface engineering, and other fields. Employing magnetron sputtering technology, it enhances ionization efficiency through magnetic fields, thereby achieving high-quality and uniform thin-film deposition
The magnetron sputtering coater is an advanced physical vapor deposition (PVD) equipment widely used in semiconductor, optoelectronics, display technology, surface engineering, and other fields. Employing magnetron sputtering technology, it enhances ionization efficiency through magnetic fields, thereby achieving high-quality and uniform thin-film deposition.Product Features:
Efficient Coating: Utilizing magnetron sputtering technology, it boasts a high deposition rate and excellent film uniformity.
Versatile Applications: Supports a wide range of target materials and substrates, suitable for thin-film deposition on diverse materials.
Intelligent Control: Equipped with an advanced control system, it enables precise control over process parameters.
Modular Design: Facilitates maintenance and upgrades, allowing for customization of various functional modules according to specific requirements.
Environmentally Friendly: Features a low-energy design that minimizes environmental impact.Buy Information :
If you are interested in our evaporative coater, please contact us for more information and quotation.
Phone: 183-3926-3857
E-mail: jack@cysitech.com
Contact: Jack Yang
Wechat: 183 3926 3857
Technical Parameters:
Parameter Name | Description | ||
Product Name | Desk magnetron Sputter Coater | ||
Product model
| CY-MSZ254-I-RF-SS | CY-MSZ254-II-DCRF-SS | |
CY-MSZ254-I-DC-SS | |||
Vacuum chamber | Chamber material | Made of 304 stainless steel welded, with polished surface | |
Pick-and-place mode | Open the cover to take and place samples and targets | ||
Observation window | 100mm diameter vacuum window, equipped with magnetic baffle to prevent contamination | ||
Sample stage | Sample size | 100mm diameter vacuum window, equipped with magnetic baffle to prevent contamination | |
Rotation speed | Plane samples with diameter ≤300mm are available | ||
Heating temperature | Non-rotating and rotating types (0-30RPM) are available | ||
Magnetic control target | Target gun type | Ordinary target/strong magnetic target are available, and the angle is adjustable | |
Target size | Diameter 3 inches, thickness ≤3mm | ||
Sputtering power | 500W/1000W are available | ||
Sputtering method | DC sputtering/RF sputtering are available | ||
Working vacuum | 0.3-3Pa | ||
Sputtering gas | High-purity argon, purity 99.99% | ||
Vacuum measurement | Compound vacuum gauge, resistance gauge + ionization gauge, measuring range:105-10-5Pa | ||
Vacuum acquisition | Foreline pump | Pumping speed 4L/S | |
Molecular pump | Pumping speed 1200L/S | ||
Film thickness measurement | Usually equipped with CYKY film thickness measuring instrument | ||
Imported brands can also be selected, the price is calculated separately | |||
Overall dimensions | 550mm X 350mm X450mm | ||
Packing dimensions | 650mm X 450mm X650mm | ||
Packing weight | 96 KG |
The main components:
Part name | Component Description |
Equipment host | Magnetron host + RF power supply |
Water cooler | Flow rate: 10L/min |
Molecular pump set | 1 set, including a composite vacuum gauge |
Test target | Usually metal, alloy or other specific materials, etc. |
Random accessories | Auxiliary accessories (tubes, wires, wrenches, etc.) |
User manual | Standard |
Application Areas:
Semiconductor Manufacturing: Used for preparing functional thin films for integrated circuits and microelectronic devices.
Optoelectronics: Suitable for thin-film deposition in optoelectronic devices such as photovoltaic cells and LEDs.
Display Technology: Widely applied in display devices like liquid crystal displays (LCDs) and organic light-emitting diodes (OLEDs).
Surface Engineering: Employed for surface modification and coating of materials like metals, ceramics, and plastics.
Application Case: "Deposition of Silicon Carbide (SiC) on Electrode Material Samples Using Magnetron Sputtering"
The deposition of silicon carbide (SiC) film on electrode material samples via magnetron sputtering requires precise parameter control and process management. Below is a detailed step-by-step guide:
Required Equipment and Materials:
Magnetron sputtering equipment
Silicon carbide target
Electrode material samples
Vacuum pump system
Argon (Ar) and methane (CH4) or other carbon-containing gas supply system
Temperature control device (if sample temperature needs to be controlled)
Cleaning equipment (e.g., ultrasonic cleaner)
Steps:
Sample Preparation:
Cleaning Samples: Use an ultrasonic cleaner to clean the samples, typically with deionized water and ethanol, ensuring the surface is dust- and oil-free.
Drying Samples: Dry the samples with nitrogen or allow them to dry naturally in a clean environment.
Equipment Preparation:
Install Silicon Carbide Target: Securely mount the silicon carbide target in the magnetron sputtering equipment's target position.
Vacuum System Preparation: Check the vacuum system's seal to ensure no leaks.
Establishing a Vacuum Environment
Evacuating: Start the vacuum pump system to gradually reduce the chamber pressure, typically achieving a vacuum level below 10−3 Pa.
Introducing Working Gas: Introduce argon (Ar) and adjust the gas flow rate, typically with a working pressure of 10 to 100 Pa.
Magnetron Sputtering:
Pre-Sputtering Cleaning: Before coating, perform pre-sputtering cleaning on the silicon carbide target to remove oxides and contaminants from the surface, typically lasting a few minutes.
Setting Parameters:
Power: Set an appropriate power based on the equipment and target characteristics, typically ranging from tens to hundreds of watts.
Gas Ratio: Introduce a mixture of carbon-containing gas (e.g., methane (CH4)) and argon (Ar), with a typical ratio ranging from 1:9 to 1:11.
Time: Set the sputtering time based on the desired film thickness, with sputtering rates typically ranging from a few nanometers to tens of nanometers per minute.
Sample Temperature: If sample temperature control is necessary, set up the heating or cooling system.
Start Coating: Initiate the magnetron sputtering equipment to begin the SiC film deposition process.
Film Thickness and Quality Control:
Film Thickness Monitoring: Use a film thickness monitoring device (e.g., quartz crystal monitor) to monitor film thickness in real-time.
Coating Quality Inspection: After coating, use equipment such as microscopes, X-ray diffraction (XRD), and atomic force microscopy (AFM) to inspect coating quality and uniformity.
Post-Processing
Cooling Samples: If samples were heated during coating, allow them to cool to room temperature.
Sample Removal: Shut down the vacuum system, slowly introduce an inert gas (e.g., nitrogen) to atmospheric pressure, and remove the samples.
Characterization Testing:
Electrical Testing: Perform electrical performance tests to confirm the SiC film's impact on the electrode material.
Structural Analysis: Conduct microstructural and compositional analyses to ensure the SiC film's quality and adhesion.
Precautions:
Gas Purity: Ensure the use of high-purity argon and methane to avoid impurities affecting film quality.
Sputtering Parameters: Depending on the specific electrode material and application requirements, adjustments may be needed to sputtering power, gas ratios, and sputtering time.
Safety: Wear protective equipment during operation to ensure safety.
By following these steps, a uniform and strongly adhering SiC film can be successfully deposited on electrode material samples. Specific parameters and details may vary depending on the actual equipment and materials used.